Reliable RCBOs, MCBs, and RCCBs with Overcurrent Protection for Electric Vehicle Charging
As a leading manufacturer of electric vehicle (EV) charging accessories, we offer a comprehensive range of reliable and innovative circuit breakers, including RCBOs, MCBs, and RCCBs with overcurrent protection. Our products are designed to ensure the safety and efficiency of your EV charging system, meeting the highest industry standards such as IEC 62423.
Key Features:
Safety: Our RCBOs, MCBs, and RCCBs offer superior protection against overcurrent, short circuits, and earth leakage faults, ensuring the safety of your EV charging system and your home.
Reliability: We use high-quality materials and components to ensure the long-lasting performance of our products.
Innovation: We are constantly developing new and innovative solutions to meet the evolving needs of the EV charging market.
Compliance: Our products are compliant with international standards such as IEC 62423, guaranteeing their safety and reliability.
Applications:
Residential EV charging stations
Commercial EV charging stations
Public EV charging infrastructure
Industrial EV charging applications
Benefits:
Enhanced safety for your EV charging system
Increased reliability and performance
Reduced risk of electrical hazards
Peace of mind knowing your EV charging system is protected
Choose the Right Circuit Breaker for Your Needs:
RCBOs: Provide combined overcurrent and earth leakage protection.
MCBs: Offer overcurrent protection.
RCCBs: Protect against earth leakage faults.
Our commitment to sustainability:
We are committed to developing sustainable and environmentally friendly products. Our circuit breakers are designed to be energy efficient and minimize waste.
Contact us today to learn more about our EV charging accessories and how they can help you create a safe and reliable charging system.
Page Description:
EV Charging Accessories: Reliable RCBOs, MCBs, and RCCBs with Overcurrent Protection
Ensure the safety and efficiency of your EV charging system with our high-quality circuit breakers. Choose from RCBOs, MCBs, and RCCBs with overcurrent protection, meeting IEC 62423 standards. Our innovative and reliable products are perfect for residential, commercial, and industrial applications. Contact us today for more information.
32A RCD Circuit Breaker
,RCBO RCD Circuit Breaker
,IEC 62423 MCB RCCB RCBO
Product Name: |
Type B RCBO 4 Poles B32 MCB |
Rated Current: |
32A/40A/63A |
Poles: |
4Pole (3P+N) |
Rated Breaking Capacity: |
6,000A |
Rated Frequency: |
50/60Hz |
Rated Residual Operation Current: |
0.03mA |
Short-circuit Current Inc: |
Ic 10000A |
Standard: |
IEC 61008-1, IEC 62423 |
Product Name: |
Type B RCBO 4 Poles B32 MCB |
Rated Current: |
32A/40A/63A |
Poles: |
4Pole (3P+N) |
Rated Breaking Capacity: |
6,000A |
Rated Frequency: |
50/60Hz |
Rated Residual Operation Current: |
0.03mA |
Short-circuit Current Inc: |
Ic 10000A |
Standard: |
IEC 61008-1, IEC 62423 |
B Type RCCB with Overcurrent protection Type B RCBO 4 poles B32 MCB RCD Circuit Breaker
Technical Data
Mode | Electronic | ||||||||||||||||||||||||||||||
Type Rated current In |
B16,20,25,32,40,50,63A | ||||||||||||||||||||||||||||||
Poles | 2P(1P+N),4P(3P+N) | ||||||||||||||||||||||||||||||
2P 240V~ | |||||||||||||||||||||||||||||||
Rated voltage Ue Insulation voltage Ui |
4P 415V~ | ||||||||||||||||||||||||||||||
500V | |||||||||||||||||||||||||||||||
Rated frequency | 50/60Hz | ||||||||||||||||||||||||||||||
Rated residual operating current(I△n) | 30,100,300mA | ||||||||||||||||||||||||||||||
Break time under I△n | ≤0.1s(S type <0.5s) | ||||||||||||||||||||||||||||||
Rated breaking capacity | 6,000A | ||||||||||||||||||||||||||||||
Energy limiting class | 3 | ||||||||||||||||||||||||||||||
Rated impulse withstand voltage(1.5/50) Uimp | 4,000V | ||||||||||||||||||||||||||||||
Dielectric test voltage at ind.Freq. for 1min | 2kV | ||||||||||||||||||||||||||||||
Pollution degree | 2 | ||||||||||||||||||||||||||||||
Thermo-magnetic release characteristic | B,C |
Application
- The function of lightning and surge protectionsystemsistoprotect the devices,functionalisolations and overvoltage-sensitive consumerequipments ofenergy distributionsystemsagainstall lightning and overvoltage
- damages.whole building;the outdoor lightningprotection system is generally notsufficienttoeliminate suchmalfunctions.At most of types,thedefected protection devicecan be made
- operative again by changing the damaged insert;these variants are also equipped with bothopticaloperation signaland auxiliary statuscontact.
Mechanical Features
Electrical life | 4,000 Cycles | ||||||||||||||||||||||||||||||
Mechanical life Contact position indicator |
10,000 Cycles Yes |
||||||||||||||||||||||||||||||
Protection degree | IP20 | ||||||||||||||||||||||||||||||
Reference temperature for setting of thermal element | 30℃ | ||||||||||||||||||||||||||||||
Ambient temperature (with daily average≤35℃) | -5℃~+40℃ | ||||||||||||||||||||||||||||||
Storage temperature | -25℃~+70℃ |
Installation
Terminal connection type Terminal size top/bottom for cable |
Cable/Pin-type busbar/U-type busbar 25mm2 18-3AWG |
||||||||||||||||||||||||||||||
Terminal size top/bottom for busbar | 25mm2 18-3AWG | ||||||||||||||||||||||||||||||
Tightening torque | 2.5Nm 22In-lbs | ||||||||||||||||||||||||||||||
Mounting | On DIN rail EN60715(35mm) by means of fast clip device | ||||||||||||||||||||||||||||||
Connection | From top |
Auxiliary contact | EKM1-OF | ||||||||||||||||||||||||||||||
Alarm contact Shunt release |
EKM1-FB EKM1-MX |
Lagging Angle 0° |
I△n>0.01A 0.35I△n≤I△≤1.4I△n |
I△n≤0.01A 0.35I△n≤I△≤2I△n |
|||||||||||||||||||||||||||||
90° | 0.25I△n≤I△≤1.4I△n | 0.25I△n≤I△≤2I△n | |||||||||||||||||||||||||||||
135° | 0.11I△n≤I△≤1.4I△n | 0.11I△n≤I△≤2I△n |
Certification:TUV