Experts Available 24/7 365
[email protected]
Experts Available 24/7 365


B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma
B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma  B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma 

B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma

  • Brand: OEM
  • Product Code: ANS-RCD-63A
  • Availability: In Stock
  • $70



Quote Now
OR
Get Samples
EV Charging Cables wholesalers

Product Information

400V RCCB, 63 Amp 4 Pole, 30mA Residual Current Circuit Breaker, ELCB, RCCB Earth Leakage Protection, 4 Pole RCCB, Electrical Safety Breaker, Industrial RCCB, 30mA RCCB, Residual Current Breaker 63 Amp
Product Listing:

Protect your EV charging infrastructure with our top-of-the-line 400V RCCB, a 63 Amp 4 Pole Residual Current Circuit Breaker with 30mA sensitivity. This ELCB (Earth Leakage Circuit Breaker) offers superior protection against earth leakage faults, ensuring the safety of your personnel and equipment during EV charging.

Key Features:

400V AC operation: Compatible with high-voltage EV charging systems.
63 Amp capacity: Suitable for high-power charging applications.
4 Pole design: Provides comprehensive protection for all phases and neutral.
30mA sensitivity: Detects even the smallest earth leakage currents for maximum safety.
Compliant with international standards: Ensures reliability and performance.
Durable construction: Built to withstand harsh industrial environments.
Easy installation: Designed for quick and straightforward mounting.

Applications:

EV charging stations
Industrial facilities
Commercial buildings
Data centers
Hospitals
And more

Benefits:

Enhanced safety: Protects against electrical shock and fire hazards.
Increased reliability: Prevents damage to equipment and infrastructure.
Improved efficiency: Minimizes downtime and maintenance costs.
Peace of mind: Ensures compliance with safety regulations.

As a leading manufacturer of EV charging accessories, we offer a wide range of RCCBs to meet your specific needs. Our team of experts can help you choose the right product for your application.

Contact us today to learn more about our 400V RCCB and other EV charging solutions.

Page Description:

400V RCCB, 63 Amp 4 Pole, 30mA Residual Current Circuit Breaker (ELCB) for enhanced EV charging safety. Protect your personnel and equipment with our high-quality RCCBs, compliant with international standards and offering superior earth leakage protection. Contact us for expert advice and a wide range of EV charging solutions.

Highlight:

30ma RCCB Residual Current Circuit Breaker

,

400V RCCB Residual Current Circuit Breaker

,

ELCB 63 Amp 4 Pole 30ma

Product Name:
63 Amp 30mA Type B 10KA RCD
Rated Current:
63A
Poles:
3 Phase 4Pole (3P+N)
Rated Voltage:
4Pole: 400V/415V
Rated Frequency:
50/60Hz
Rated Residual Operation Current:
30mA
Short-circuit Current Inc:
Ic 10000A
Standard:
IEC 61008-1, IEC 62423
Logo:
Support Customzation
Product Name:
63 Amp 30mA Type B 10KA RCD
Rated Current:
63A
Poles:
3 Phase 4Pole (3P+N)
Rated Voltage:
4Pole: 400V/415V
Rated Frequency:
50/60Hz
Rated Residual Operation Current:
30mA
Short-circuit Current Inc:
Ic 10000A
Standard:
IEC 61008-1, IEC 62423
Logo:
Support Customzation
B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma

B Type RCCB Residual Current Circuit Breaker DC ELCB 2P 63 Amp 30mA Type B 10KA RCD

  • Residual current circuit breakers RCCBs are the safest devices for detecting and preventing the tripping of leakage currents, thus ensuring protection against electric shocks caused by indirect contact.
  • These devices must be used in series with MCBs or fuses to protect them from the potentially damaging thermal and dynamic stress of any overcurrent.
  • They can also be used as the main disconnecting switch upstream of any derived MCB.
  • The main purpose of the RCCB is to provide protection against direct and indirect contact with people or livestock, as well as possible fire, from shocks caused by electrical leakage, which can be fatal.

Technical Data

Mode Electromagnetic
Type(wave form of the earth leakage sensed)
Rated current In
63A
Poles 4P
Rated voltage Ue 4P 415V~
Insulation voltage Ui 500V
Rated frequency 50/60Hz
Rated residual operation current(I△n) 30mA
Rated residual operating current(I△dc) 6mA
Rated residual making and breaking capacity (I△m) 500A(In≤40A), 10In(In>40A)
Short-circuit current Inc= I△c 10,000A 10000
Break time under I△n Rated impulse withstand voltage(1.5/50) Uimp ≤0.1s 4000V
Dielectric test voltage at ind.Freq. for 1min 2.5kV
Electrical life 2,000 Cycles
Mechanical life 4,000 Cycles

 

Installation

 

Contact position indicator Yes
Protection degree
Ambient temperature(with daily average≤35℃)
IP20
-5℃~+40℃
Storage temperature -25℃~+70℃
Terminal connection type Cable/Pin-type busbar/U-type busbar
Terminal size top/bottom for cable 35mm2 18-3AWG
Terminal size top/bottom for busbar 35mm2 18-3AWG
Tightening torque 2.5Nm 22In-lbs
Mounting On DIN rail EN60715(35mm) by means of fast clip device
Connection Power supply in both directions

 

Tripping Current Range
Lagging Angle
I△n>0.01A
0.35I△n≤I△≤1.4I△n
I△n≤0.01A
0.35I△n≤I△≤2I△n
90° 0.25I△n≤I△≤1.4I△n 0.25I△n≤I△≤2I△n
135° 0.11I△n≤I△≤1.4I△n 0.11I△n≤I△≤2I△n

B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma 0

B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma 1

RCD Protection 

  • This device is very important in electrical wiring installations as a life protection device against electric shocks. Other circuit breakers can only detect overcurrent and short-circuit faults, but not leakage.
  • This is why the RCCB is very important, only this device can detect electrical leakage, which can cause injury or death to people and can lead to the risk of fire. When designing your distribution panel board, please ensure that this device is included in our planning of the installation.
  • Protection in case of indirect contact (indirect protection of persons) and fault protection when disconnection is caused by an impermissibly high touch voltage caused by a short circuit in an exposed conductive part.
  • Protection in case of direct contact (direct protection of persons) - disconnection as additional protection in case of direct contact with live conductors. If the device has a rated residual current of In - 30 mA, dangerous inrush currents are disconnected within a short time.

B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma 2

B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma 3

Certification:TUV

 

B Type 400V RCCB Residual Current Circuit Breaker ELCB 63 Amp 4 Pole 30ma 4

There are no reviews for this product.

Write a review

Note: HTML is not translated!
Bad           Good
Captcha

Related Products

10KA Type B 63A RCD Circuit Breaker For Leackage Protection

10KA Type B 63A RCD Circuit Breaker For Leackage Protection

63A RCD Circuit Breaker: Ultimate Protection for Your EV Charging StationLooking for the best RCD circuit breaker for your EV charging station? Look no further than our 63A RCD Circuit Breaker!This top-of-the-line device offers unparalleled protection against earth leakage faults, ensuring the safety of your charging station and your electric vehicle.Here's what makes our 63A RCD Circuit Breaker stand out:Type B RCD: Provides superior protection against both AC and pulsating DC earth leakage currents, essential for EV charging applications.10kA Residual Current Circuit Breaker: Offers exceptional fault protection, safeguarding your equipment and preventing fires.Leakage Protection RCD: Detects even the smallest earth leakage currents, ensuring your safety and preventing shocks.Electrical Safety Breaker: Complies with the latest safety standards, guaranteeing reliable and dependable protection.Type B Residual Current Circuit Breaker: Specifically designed for EV charging stations, offer..

$70.00
Quote
DC 6mA 4P Residual Current Protection Device 50 / 60Hz Rated Frequency

DC 6mA 4P Residual Current Protection Device 50 / 60Hz Rated Frequency

DC 6mA Residual Current Protection Device: Enhanced Safety for Your EV Charging NeedsProtect your electric vehicle (EV) charging setup with our top-of-the-line DC 6mA Residual Current Protection Device (RCPD). This innovative device offers unparalleled safety and reliability, ensuring peace of mind while charging your EV.Key Features:Unmatched Sensitivity: Featuring a 6mA residual current trip threshold, our RCPD provides the highest level of protection against electrical faults, exceeding industry standards.4-Pole Design: This comprehensive solution safeguards all live conductors, including neutral, for complete circuit protection.DC Circuit Compatibility: Specifically designed for DC circuits commonly found in EV charging systems, ensuring optimal performance and compatibility.50/60Hz Compatibility: Works seamlessly with both 50Hz and 60Hz electrical systems, offering global versatility.Compact and Efficient: Its space-saving design integrates seamlessly into your existing electrical..

$70.00
Quote
Type B IP20 RCD Circuit Breaker 40A 3 Phase 4 Pole MCB Electromagnetic Mode

Type B IP20 RCD Circuit Breaker 40A 3 Phase 4 Pole MCB Electromagnetic Mode

Type B RCD Circuit Breaker 40A: Protect Your EV Charging Station with ConfidenceEnsure the safety and reliability of your EV charging station with our Type B RCD Circuit Breaker 40A. This advanced circuit breaker offers superior protection against earth leakage currents, safeguarding your investment and providing peace of mind.Key Features:Type B RCD: Detects both AC and pulsating DC earth leakage currents, crucial for EV charging applications.40A Rated Current: Suitable for high-power charging stations.IP20 Protection: Dustproof and protected against accidental contact.Electromagnetic Mode: Immune to electromagnetic interference, ensuring reliable operation.3 Phase 4 Pole MCB: Provides comprehensive protection for all three phases of your EV charging circuit.Compact Design: Saves valuable space in your electrical panel.Easy Installation: Simple and straightforward mounting process.Applications:EV charging stationsSolar power systemsIndustrial equipmentCommercial buildingsResidential a..

$70.00
Quote
2P / 4P 40A RCCB Circuit Breaker AC 30mA Electrical Life 2000 Cycles

2P / 4P 40A RCCB Circuit Breaker AC 30mA Electrical Life 2000 Cycles

40A RCCB Circuit Breaker: The Ultimate Protection for Your EV Charging Station40A RCCB Circuit Breaker is a vital component for ensuring the safety and reliability of your EV charging station. This innovative device combines the functions of both a Miniature Circuit Breaker (MCB) and a Residual Current Circuit Breaker (RCCB), offering comprehensive protection against overloads, short circuits, and dangerous ground faults.Main Series:2P RCCB Circuit Breaker: Ideal for single-phase charging stations, providing protection for both live and neutral wires.4P RCCB Circuit Breaker: Designed for three-phase charging stations, offering comprehensive protection for all three phases and the neutral wire.Applications:Residential EV charging stationsCommercial EV charging stationsPublic EV charging stationsIndustrial EV charging stationsKey Features:High breaking capacity: 40A, ensuring reliable protection against high currents.Sensitivity: 30mA, providing fast and effective protection against grou..

$70.00
Quote
Warranty, ev charge supplier

We provide a 1-year warranty on every item we sell

Our free 1-year warranty makes every purchase a dependable, reliable investment in your company's future.

Need More Help?

From product insights to customer service needs, our experienced service team will focus on getting you what you need, fast.

contact us, ev charge supplier
11
22
33